5.5 Administrator Mode Operations |
|
|
|
|
|
| 5 |
|
|
|
|
|
|
|
|
| |
9 Check that the left |
|
|
|
|
|
|
|
|
margin of the test | b |
|
|
|
|
|
|
|
pattern is between |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
2.5mm and 3.5 mm. If the left margin is within the specified range, skip to step 14.
b: 3.0 mm ± 0.5 mm
10 If the left margin is less than 2.5 mm, touch to specify the desired positive adjustment (between +0.1 mm and +3.0 mm).
11 If the left margin is more than 3.5 mm, touch to specify the desired negative adjustment (between
12 Press the [Start] key. The adjusted test pattern is printed on 11 ⋅
13 Check the print result to make sure that the left margin is adjusted to between 2.5 mm and 3.5 mm.
❍If more adjustment is necessary, return to step 8 and repeat the adjustment procedure.
14 Touch [Enter].
15 Touch [Fin. Time] again in the next three screens that appear.
Utility Mode Operations Chapter 5
CF2002/CF3102 |