Multi-Tech Systems RF500S manual Use Local Client List

Models: RF500S

1 138
Download 138 pages 38.02 Kb
Page 56
Image 56

Chapter 4 – Software Installation and Configuration

7a. If you selected Remote Access Selection from the Asynchronous Port Function screen, the Remote Access screen displays.

You must define the location of your remote user account database by selecting Use Local Client List or Use RADIUS Server.

Figure 7 – Remote Access with Default Screen: Use Local Client List

Use Local Client List

Note: The Local Client List allows you to add a maximum of 64 users.

The Local Client List is an authentication database of user names, passwords and dial-in options for each remote user. Enter the following information for each client:

User Name to authenticate the remote dial-in user.

Password to authenticate the remote dial-in user. Passwords are limited to 16 characters.

Re-enter the remote dial-in user’s password for Verification.

Select one of the following three Callback Types for each remote client:

No Callback: This option allows the remote user to immediately connect to the network after being authenticated. No Callback is the default.

Fixed Callback: This option allows you to specify a fixed callback telephone number for the user. After the PPP negotiation, the device will disconnect, and then callback the telephone number you entered in the callback

RouteFinder RF500S User Guide

56

Page 56
Image 56
Multi-Tech Systems RF500S manual Use Local Client List