116NT8D72 and QPC720 PRI card installation

Table 30

Cable for the NT8D72 PRI card for Multi Group systems

Cable

 

From

Des.

 

Con.

To

 

Des.

Con.

Notes

 

 

 

 

 

 

 

 

 

 

 

QCAD130

 

PRI card

 

 

 

J1

 

Clock contro

CC-0

1

 

 

 

 

 

 

 

 

ller

 

 

 

 

 

 

 

 

 

 

 

 

 

QCAD130

 

PRI card

 

 

 

J1

 

Clock contro

CC-0

2

 

 

 

 

 

 

 

 

ller

 

 

 

 

 

 

 

 

 

 

 

 

 

QCAD130

 

PRI card

 

 

 

J2

 

Clock contro

CC-1

1

 

 

 

 

 

 

 

 

ller

 

 

 

 

 

 

 

 

 

 

 

 

 

QCAD130

 

PRI card

 

 

 

J2

 

Clock contro

CC-1

2

 

 

 

 

 

 

 

 

ller

 

 

 

 

 

 

 

 

 

 

 

 

 

QCAD110

 

Clock contro

CC-0

 

J3

Junctor

 

JCTR

J11

3

 

 

ller

 

 

 

board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QCAD110

 

Clock contro

CC-1

 

J3

Junctor

 

JCTR

J12

 

 

 

ller

 

 

 

board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QCAD124

 

PRI card

 

 

J3

Network

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

QCAD328A

 

PRI card

 

 

J5

DCHI card

 

 

J2

5

 

 

 

 

 

 

 

 

 

 

 

NTND26

 

PRI card

J5

 

 

MSDL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QCAD128

 

PRI card

 

 

J4

I/O Panel

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

QCAD133

 

I/O Panel

 

 

 

Patch Panel

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

QCAD129

 

PRI card

 

 

J6

I/O Panel

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

RS-232

 

I/O Panel

 

 

 

Echo Cance

 

 

 

 

 

 

 

 

 

 

ller

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-232

 

PRI card

 

 

J6

Echo Cance

 

 

 

7

 

 

 

 

 

 

ller

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1: Only when primary clock source.

 

 

 

 

 

 

Note 2: Only when secondary clock source.

 

 

 

 

 

Note 3: multigroup junctor board connection.

 

 

 

 

 

Note 4: Run to connector on network pack.

 

 

 

 

 

Note 5: Run directly to DCHI card.

 

 

 

 

 

 

Note 6: Run by means of cabinet I/O panel to CSU, echo canceller, or cross connect terminal.

Note 7: Run by means of cabinet I/O panel to crossconnect terminal or echo canceller from non

shielded system.

 

 

 

 

 

 

 

 

 

Note 8: No additional cabling is required for multiple PRIs. The D-channel is associated through

software in LD17, prompt PRI.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nortel Communication Server 1000

 

 

 

 

 

ISDN Primary Rate Interface Installation and Commissioning

 

 

 

 

 

NN43001-301 02.03 Standard

 

 

 

 

 

 

Release 5.5 7 December 2007

 

 

 

Copyright © 2003-2007, Nortel Networks

Page 116
Image 116
Nortel Networks NN43001-301 manual QCAD110, Jctr, Msdl QCAD128, QCAD133, QCAD129