PRI software implementation 273

in the Software Input Output Reference — Maintenance for further information.

The following is a summary of the tasks in this section:

1."LD 17 - Adding a PRI card" (page 273)

2."LD 17 - Adding a DCHI or DDCH" (page 273)

3."LD 15 - Defining a PRI customer" (page 275)

4."LD 16 - Defining a PRI service route" (page 276)

5."LD 14 - Defining service channels and PRI trunks" (page 277)

6."LD 73 - Defining system timers and clock controller parameters" (page 277)

7."LD 73 - Defining PRI parameters and thresholds" (page 278)

8."LD 73 - Changing trunk pad category values" (page 280)

LD 17 - Adding a PRI card

Prompt

Response

Description

 

 

 

REQ

CHG

Change data.

TYPE

CFN

Configuration data block.

CEQU

YES

Changes to common equipment.

PRI2

xx

The PRI2 digital card number, where: xx = 1-9 (Option 11C main

 

 

cabinet), 11-19 (IP expansion cabinet 1), 21-29 (IP expansion

 

 

cabinet 2), 31-39 (IP expansion cabinet 3), 41-49 (IP expansion

 

 

cabinet 4.)

 

 

xx = 11-14, 21-24, 31-34, 41-44 of the first, second, third and

 

 

fourth Media Gateway, respectively.

 

 

 

LD 17 - Adding a DCHI or DDCH

 

 

 

 

Prompt

Response

Description

 

 

 

REQ

CHG

Change data.

TYPE

CFN

Configuration data block.

 

 

 

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007

Copyright © 2003-2007, Nortel Networks

Page 273
Image 273
Nortel Networks NN43001-301 manual Change data, PRI2 digital card number, where xx = 1-9 Option 11C main