Nortel Networks NN43001-301 manual Install the NT5D97 DDP2, Switch Setting Dnum LD

Models: NN43001-301

1 306
Download 306 pages 36.63 Kb
Page 139
Image 139

Install the NT5D97 DDP2 139

 

 

 

Switch Setting

 

 

 

 

 

 

 

DNUM (LD 17)

1

2

 

3

4

 

 

 

 

 

 

13

ON

OFF

 

ON

ON

 

 

 

 

 

 

14

OFF

ON

 

ON

ON

 

 

 

 

 

 

15

ON

ON

 

ON

ON

 

 

 

 

 

 

Install the NT5D97 DDP2

Use Procedure 14 "Install the NT5D97 on Large Systems" (page 139) to install the NT5D97 on Large Systems.

CAUTION

The static discharge bracelet located inside the cabinet must be worn before handling circuit cards. Failure to wear the bracelet can result in damage to the circuit cards.

Procedure 14

Install the NT5D97 on Large Systems

Step Action

1Determine the cabinet and shelf location where the NT5D97 is to be installed. The NT5D97 can be installed in any card slot in the Network bus.

2Unpack and inspect the NT5D97and cables.

3If a DDCH is installed, refer to the section "NTBK51 DDCH installation and removal" (page 91).

4Set the option switches on the NT5D97 card before installation. Refer to "NT5D97AA/AB DIP switch settings" (page 129).

The ENB/DIS (enable/disable faceplate switch) must be OFF (DIS) when installing the NT5D97, otherwise a system initialize can occur. The ENB/DIS on the NT5D97 corresponds to the faceplate switch on the QPC414 Network card.

5Install NT5D97 card in the assigned shelf and slot.

6Set the ENB/DIS faceplate switch to ON.

If the DDCH is installed, the DDCH LED should flash three times.

7If required, install the I/O adapters in the I/O panel.

8Run and connect the NT5D97 cables

Nortel Communication Server 1000