Nortel Networks NN43001-301 Valid switch combinations, Port 0 settings Mode Switch setting

Models: NN43001-301

1 306
Download 306 pages 36.63 Kb
Page 81
Image 81

Set up the NT6D11AB, NT6D11AE, NT6D11AF DCHI 81

Table 21

Protocol selection switch settings

Protocol

 

Switch Setting

 

 

 

 

 

SW3.1

 

SW3.2

 

 

 

 

DPNSS1

0

 

0

 

 

 

 

ISDN

1

 

1

 

 

 

 

Valid switch combinations

The following are the only allowable switch setting combinations (not including address switch settings).

Port 0

Port 0 can be configured as asynchronous ESDI, or disabled. If the port is configured as disabled, it will not be visible to the system CPU. Refer to Table 22 "Port 0 settings" (page 81).

Table 22

Port 0 settings

Mode

 

Switch setting

 

 

 

 

 

 

 

SW1.1

SW1.2

SW3.1

SW3.2

 

 

 

 

 

Asynchronous ESDI

1

0

0

0

 

 

 

 

 

Asynchronous ESDI

1

0

1

1

 

 

 

 

 

Port disabled

1

1

-

-

 

 

 

 

 

Port 1

The following are the only valid emulation mode combinations. If the port is configured as disabled, it will not be visible to the system CPU. Refer to Table 23 "Port 1 settings" (page 81).

Note: The ISDN emulation must be selected.

Table 23

Port 1 settings

Mode

Emulates

 

Switch setting

 

 

 

 

 

 

 

 

 

SW2.1

SW2.2

SW3.1

SW3.2

 

 

 

 

 

 

DPNSS1

NT5K35

0

0

0

0

 

 

 

 

 

 

ISDN

NT6D11

0

0

1

1

 

 

 

 

 

 

Expanded

NT5K75

0

1

0

0

DPNSS1

 

 

 

 

 

 

 

 

 

 

 

Port disabled

 

1

1

-

-

 

 

 

 

 

 

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007

Copyright © 2003-2007, Nortel Networks

Page 81
Image 81