Procedure 16

Install the NT5D12 on Large Systems

Step Action

1Determine the cabinet and shelf location where the NT5D12 card is to be installed. The NT5D12 can be installed in any card slot in the Network bus, subject to the cautionary note below.

CAUTION

Some installed-based systems can have a Bus Terminating Unit (BTU) already installed. This can interfere with a selected NT5D12 card location. In such cases, the NT5D12 should be installed in an alternate network bus card slot location.

2Unpack and inspect circuit cards and cables.

3If a DDCH is to be installed, refer to "NTBK51 DDCH installation and removal" (page 91).

4Set the option switches on the NT5D12 circuit card before installation. Refer to "NTBK51 DDCH installation and removal" (page 91).

S1 (faceplate switch) must be OFF (DIS) when installing the NT5D12. S1 on the NT5D12 corresponds to the faceplate switch on the QPC414 Network card.

5Install the NT5D12 circuit card in the assigned shelf and slot.

6Add related office administration data into the system memory.

7If required, install the I/O adapters in the I/O panel.

8Run and connect the NT5D12 cables.

CAUTION

Clock Controller cables connecting the Clock Controller and NT5D12 card must NOT be routed through the center of the cabinet past the power harness. Instead, route them around the outside of the equipment shelves.

9If required, install connecting blocks at the MDF or wall mounted crossconnect terminal.

10If required, designate connecting blocks at the MDF or wall mounted crossconnect terminal.