Nortel Networks NN43001-301 manual Chty BCH, Ctyp, Inac YES, Type TIE

Models: NN43001-301

1 306
Download 306 pages 36.63 Kb
Page 216
Image 216

2161.5 Mb PRI implementation

Prompt

 

Response

 

Description

 

 

 

 

 

- - PNI

 

(0) 1-32700

 

Private Network Identifier. Each customer data block must

 

 

 

 

have a unique PNI when multi-customer option is equipped.

 

 

 

 

PNI = 1 is typical for CUST = 0. It must be matched by

 

 

 

 

the PNI in the far-end RDB.

 

 

 

 

Note: Using the default value of PNI = 0, prevents operation

 

 

 

 

of features like NRAG, NACD and NMS.

IFC

 

xx

 

Interface type.

- CHTY

 

BCH

 

Signalling type - prompted if DTRK is YES. D-channel

 

 

 

 

signalling for B-channels.

- CTYP

 

<CR>

 

Call Type. Enter the call type to be associated with the

 

 

 

 

outgoing route for direct dialing using the trunk access

 

 

 

 

code (instead of NARS access code).

 

 

 

 

See the Software Input Output Administration

 

 

 

 

(NN43001-611)for a listing of possible responses.

- INAC

 

YES

 

Insert ESN Access Code based on NARS/BARS call

 

 

 

 

type for incoming calls on TIE routes only. If NARS is

 

 

 

 

equipped, this feature inserts AC1 or AC2, depending on

 

 

 

 

the responses to AC2 in LD 15 Customer Data Block.

 

 

 

 

For NARS/BARS call types, INAC bypasses incoming digit

 

 

 

 

insertion specified by INST in LD 16 Route Data Block.

 

 

 

 

Unknown call types, including CDP steering codes, are

 

 

 

 

not affected by INAC, and do not bypass digit insertion

 

 

 

 

specified by INST.

 

 

 

 

INAC must be set to YES to support features such as

 

 

 

 

Network ACD and Network Message Services, which

 

 

 

 

depend on non-call associated TCAP facility messages.

 

 

 

 

 

LD 14 - Defining service channels and PRI trunks

 

 

 

Prompt

Response

Description

 

 

 

REQ

NEW

Add new data.

 

CHG

Change existing data.

 

 

 

When assigning several members at once use the multiple

 

 

 

create command NEW XX.

TYPE

TIE

TIE Trunk only, allowed between MSL-1.

TN

l ch

Loop and channel for digital trunks

 

 

 

 

 

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007

Copyright © 2003-2007, Nortel Networks

Page 216
Image 216
Nortel Networks NN43001-301 manual Chty BCH, Ctyp, Inac YES, LD 14 Defining service channels and PRI trunks, Type TIE