Nortel Networks NN43001-301 manual LD 73 Defining the 2.0 Mb DTI system timers

Models: NN43001-301

1 306
Download 306 pages 36.63 Kb
Page 252
Image 252

2522.0 Mb DTI implementation

Prompt

Response

Description

 

 

 

GP2

T2 mt dt ct ot

Group 2 error thresholds.

 

 

This is the maximum amount of time that can occur before

 

 

software checks the associated thresholds of 120 to 32640

 

 

msec and rounds it to the closest multiple of 128 msec. T2 error

 

 

count values are in the range 1-(20)-255. NC = Error count

 

 

values are in the range 1-255.

 

 

mt = Maintenance threshold time (MNT).

 

 

dt = No new data calls threshold time (NNDC).

 

 

ct = No new calls threshold time (NNC).

 

 

ot = Out of service threshold time (OOS).

 

 

Note: The following requirements must be met for this input: mt

 

 

= >dt = >ct = >ot.

FRFW

YES (NO)

This 2.0 Mb DTI card is (is not) equipped with special Firmware

 

 

for France.

 

 

 

LD 73 - Defining the 2.0 Mb DTI system timers

 

 

 

Prompt

Response

Description

 

 

 

REQ

NEW

Add or Change Digital Trunk Interface data block.

 

CHG

 

TYPE

DTI2

2.0 Mb DTI.

FEAT

SYTI

Change the switch timers and counters for 2.0 Mb DTI.

 

 

There is only one such block per switch.

MAND

0-(15)-1440

Maintenance guard time in minutes.

NCSD

0-(15)-1440

New call suppression guard time in minutes and seconds.

 

1S-59S

 

OSGD

0-(15)-1440

Out-of-service guard time in minutes.

OOSC

0-(5)-127

Out-of-service occurrences since midnight (DTI disabled).

PERS

0-(100)-254

Persistence timer in milliseconds for far-end problems.

DBNC

(10)-32

Debounce timer in milliseconds.

CCO

xx

Card slot number for Clock Controller 0.

 

<CR>

No change for defaults.

 

X

To remove clock controller data.

PREF CCO

xx

Card number of PRI/DTI/SILC containing the primary clock

 

 

reference for the main cabinet

SREF CCO

xx

Card number of PRI/DTI/SILC containing the primary clock

 

 

reference for the main cabinet

CC1

xx

Card number for Clock Controller 1.

 

 

 

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007

Copyright © 2003-2007, Nortel Networks

Page 252
Image 252
Nortel Networks NN43001-301 manual LD 73 Defining the 2.0 Mb DTI system timers