Nortel Networks NN43001-301 Procedure Installing the NTAK09, Procedure Connecting the cables

Models: NN43001-301

1 306
Download 306 pages 36.63 Kb
Page 209
Image 209

Install PRI hardware 209

Installing the NTAK09

Refer to Table 74 "Shelf slot assignments for NTRB21, NTAK09, and NTAK20" (page 202) to determine the slot assignment for the NTAK09 DTI/PRI circuit card appropriate to the system.

The NTAK09 DTI/PRI card is installed only in the Media Gateway. It is not supported in the Media Gateway Expansion.

Procedure 29

Installing the NTAK09

Step Action

1Check for available card slots in the base and expansion cabinets, and Media Gateway systems and print the configuration record to determine which slots can be used. To do this, enter the following command in LD 22:

PRT CFN

2Hold the NTAK09 by the lock latch, unlock the latch, and slide the card into the cabinet.

Note: Refer to Table 74 "Shelf slot assignments for NTRB21, NTAK09, and NTAK20" (page 202) to determine the correct slot in which to insert the card.

—End—

The only cable required to support the NTAK09 DTI/PRI circuit card is the NTBK04 cable. The cable is twenty feet long. If additional distance is required, the NT8D97AX fifty-foot extension is available up to a 600 foot maximum. Table 76 "DS-1 line interface pinout for NTBK04 cable" (page

210)gives pinout information for the NTBK04.

Procedure 30

Connecting the cables

Step Action

1Connect the NTBK04 cable to a 50-pin Amphenol connector on the cabinet.

For a Small System, the Amphenol connector is located below the card slot in which the NTAK09 circuit card is installed.

2Connect the other end of the cable to the CSU or DSX-1 cross connect.

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007

Copyright © 2003-2007, Nortel Networks

Page 209