Cable requirements 117

Cable

From

Des.

Con.

To

Des.

Con.

Notes

 

 

 

 

 

 

 

 

QCAD133

PRI card

 

J4

Patch Panel

 

 

7

 

 

 

 

 

 

 

 

RS-232

PRI card

 

J6

Echo Cance

 

 

7

 

 

 

 

ller

 

 

 

 

 

 

 

 

 

 

 

Note 1: Only when primary clock source.

Note 2: Only when secondary clock source.

Note 3: multigroup junctor board connection.

Note 4: Run to connector on network pack.

Note 5: Run directly to DCHI card.

Note 6: Run by means of cabinet I/O panel to CSU, echo canceller, or cross connect terminal.

Note 7: Run by means of cabinet I/O panel to crossconnect terminal or echo canceller from non shielded system.

Note 8: No additional cabling is required for multiple PRIs. The D-channel is associated through software in LD17, prompt PRI.

Table 31

Cable for the QPC720 PRI card for Half and Multi Group systems

Cable

From

Des.

Con.

To

Des.

Con.

Comments

 

 

 

 

 

 

 

 

For half group only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QCAD130

QPC720

 

J1

QPC471/

CC-0

J2

Only when

NT8D79xx

 

 

 

QPC775

 

 

primary clock

 

 

 

 

 

 

 

source.

 

 

 

 

 

 

 

 

QCAD130

QPC720

 

J1

QPC471/

CC-0

J1

Only when

NT8D79xx

 

 

 

QPC775

 

 

secondary clock

 

 

 

 

 

 

 

source.

 

 

 

 

 

 

 

 

NTND26

QPC720

 

J5

NT6D80

 

 

 

 

 

 

 

 

 

 

 

For single group only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QCAD130

QPC720

 

J2

QPC471/

CC-1

J2

Only when

NT8D79xx

 

 

 

QPC775

 

 

primary clock

 

 

 

 

 

 

 

source.

 

 

 

 

 

 

 

 

QCAD130

QPC720

 

J2

QPC471/

CC-1

J1

Only when

NT8D79xx

 

 

 

QPC775

 

 

secondary clock

 

 

 

 

 

 

 

source.

 

 

 

 

 

 

 

 

QCAD125

QPC471/

CC-0

J3

QPC471/

CC-1

J3

Clock controller

NT8D75xx

QPC775

 

 

QPC775

 

 

back-up.

 

 

 

 

 

 

 

 

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007

Copyright © 2003-2007, Nortel Networks

Page 117