NT5D97AA/AB DIP switch settings 131

Trunk interface switches for NT5D97AA/AB

Impedance level and unit mode

The S9/S15 switch selects the impedance level and loop operation mode on DEI2 OR PRI2. Refer to Table 38 "Impedance level and loop mode switch settings" (page 131).

Table 38

Impedance level and loop mode switch settings

Switch

Description

S9/S15 Switch Setting

 

 

 

1

Impedance level

OFF - 120 ohm

 

 

ON - 75 ohm

 

 

 

2

Spare

X

 

 

 

3

Spare

X

 

 

 

4

Unit mode

OFF - Loop operates in the DTI2 mode

 

 

ON - Loop operates in the PRI2 mode

 

 

 

Transmission mode

A per-trunk switch (S4/S10) provides a selection of the digital trunk interface type. Refer to Table 39 "Impedance level and loop mode switch settings" (page 131).

Table 39

Impedance level and loop mode switch settings

Description

S4/S10 switch settings

 

 

E1

OFF

 

 

Not used

 

 

 

Line build out

A per-trunk set of three switches (S5/S11, S6/S12 and S7/S13) provides the dB value for the line build out. Refer to Table 40 "Trunk interface line build out switch settings" (page 131).

Note: Do not change this setup.

Table 40

Trunk interface line build out switch settings

Description

Switch setting

 

 

 

 

 

 

 

S5/S11

S6/S12

S7/S13

 

 

 

 

0dB

OFF

OFF

OFF

 

 

 

 

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007

Copyright © 2003-2007, Nortel Networks

Page 131
Image 131