Nortel Networks NN43001-301 manual Mfao YES no, Szni YES no, Mff Crc, Aff

Models: NN43001-301

1 306
Download 306 pages 36.63 Kb
Page 250
Image 250

2502.0 Mb DTI implementation

Prompt

Response

Description

 

 

 

MFAO

YES (NO)

DTI card will or will not set bit 3 of timeslot 0 if loss of

 

<CR>

Multiframe Alignment Signal (MFAS) occurs.

 

 

2.0 Mb DTI default = NO

 

 

<cr> = no change is required

 

 

 

SZNI

YES (NO)

PSTN incoming seizure during lockout of MFAS and far-end

 

 

fault states allowed (denied)

 

 

 

MFF

CRC

Multiframe format - Cyclic Redundancy Check (CRC 4)

 

(AFF)

Alternative Frame Format

 

 

Note: Prompted for Small Systems.

 

 

 

The following prompts and associated responses define the grade of service timers for the DTI card. Group I problems are treated individually. They are bipolar violations, bit error rate (frame alignment) slips, and CRC-4 errors.

Group II problems are treated as a group. They are bit 3 of TS0 (far-end out of service), bit 6 of TS16 (far-end lost multiframe alignment), AIS (alarm indication signal), loss of frame alignment, and loss of multiframe alignment.

Responses are interpreted as follows:

mt = Maintenance threshold time.

ct = New call suppression (hardware service removal) threshold time.

ot = Out of service threshold time.

dt = No new data calls suppression threshold time.

Each of the response times are expressed as follows:

nnnY = time in milliseconds where nnnn = 20-5000 (input to nearest 20 milliseconds.)

nnnS = time in seconds where nnn = 1-240

nnnM = time in minutes where nnn = 1-240

nnH = time in hours where nn = 1-24

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007

Copyright © 2003-2007, Nortel Networks

Page 250
Image 250
Nortel Networks NN43001-301 manual Mfao YES no, Szni YES no, Mff Crc, Aff