Nortel Networks NN43001-301 manual Trunk interface switches for NT5D97AD Trunk 0 switches

Models: NN43001-301

1 306
Download 306 pages 36.63 Kb
Page 136
Image 136

136NT5D97 Dual-port DTI2/PRI2 installation and removal

Trunk interface switches for NT5D97AD

Trunk 0 switches

Switch S12 gives the MPU information about its environment as shown in Table 46 "General purpose switches for NT5D97AD" (page 136).

Table 46

General purpose switches for NT5D97AD

Switch

Description

S9/S15 Switch Setting

 

 

 

S12_1

Impedance level

OFF - 120 ohm

 

 

ON - 75 ohm

 

 

 

S12_2

Spare

For future use

 

 

 

S12_3

Spare

For future use

 

 

 

S12_4

Unit mode

OFF - Unit operates in the DTI2 mode

 

 

ON - Unit operates in the PRI2 mode

 

 

 

Switch S2 selects the Transmission mode as shown in Table 47 "TX mode switches for NT5D97AD" (page 136).

Table 47

TX mode switches for NT5D97AD

TX mode

S2

 

 

E1

OFF

 

 

Not used

ON

 

 

Switch S3, S4, and S5 select LBO function as is Table 48 "LBO switches for NT5D97AD" (page 136).

Table 48

LBO switches for NT5D97AD

LBO setting

S3

S4

S5

 

 

 

 

0dB

OFF

OFF

OFF

 

 

 

 

7.5dB

ON

ON

OFF

 

 

 

 

15dB

ON

OFF

ON

 

 

 

 

Switch S6 selects the Receiver interface as in Table 49 "Receiver interface switches for NT5D97AD" (page 137).