Nortel Networks NN43001-301 manual Set the switches on the NTBK50, NTBK50 with switch locations

Models: NN43001-301

1 306
Download 306 pages 36.63 Kb
Page 267
Image 267

Install the NTBK50 PRI card 267

Set the switches on the NTBK50

The NTBK50 incorporates three onboard dip switches. The following tables provide information on the various settings and related functions of these switches.

Note: The ON position for all the switches is positioned toward the bottom of the card. This is indicated by a white dot printed on the board adjacent to the bottom left corner of each switch.

Figure 85

NTBK50 with switch locations

Set the switches on the circuit card according to the requirements of your installation.

Switch SW1 - DCHI configuration (NTAK93 only)

This switch enables and disables the DCHI and sets the operating mode of the DCHI. It is only used if an NTAK93 D-channel handler daughterboard is being used. It has no effect when using the NTBK51 DDCH daughterboard.

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007

Copyright © 2003-2007, Nortel Networks

Page 267
Image 267
Nortel Networks NN43001-301 manual Set the switches on the NTBK50, Switch SW1 Dchi configuration NTAK93 only