Install PRI hardware 213

LD 17 - Adding a D-channel interface

 

 

 

 

Prompt

Response

Description

 

 

 

REQ

CHG

Change existing data.

TYPE

ADAN

Action Device And Number.

- ADAN

NEW DCH xx

Add a primary D-channel (any unused SDI port.)

 

CHG DCH xx

Change a primary D-channel.

 

OUT DCH xx

Remove the primary D-channel, where:

 

 

xx =0-79.

- CTYP

DCHI

DCHI = D-channel configuration for the NTAK09 card or

 

 

NTAK93.

 

MSDL

 

 

 

MSDL = NTBK51 Downloadable D-channel daughterboard.

 

TMDI

 

 

 

TMDI = D-channel configuration on TMDI (NTRB21) card.

- CDNO

1-50

Card slot number to be used as the primary DDCH/DCHI.

 

 

Card slots 10, 20, 30, 40, and 50 are only applicable for

 

 

D-channel configuration of ISL or VNS.

- PORT

1

PORT must be set to 1.

- DES

<CR>

Designator.

- USR

PRI

D-channel is for ISDN PRI only.

- IFC

xx

Interface type.

- - DCHL

xx

PRI loop number.

- OTBF

1-(16)-127

Number of output request buffers.

 

 

Note: For a single PRI link, leave this prompt at default (16).

 

 

Add 5 output request buffers per additional link.

- DRAT

64KC

D-channel transmission rate.

- SIDE

NET (USR)

Prompted only if IFC is set to SL1.

 

 

NET = network, the controlling switch.

 

 

USR = slave to the controller.

-RLS

-RCAP

-OVLR

xx

ND2

YES (NO)

Release ID of the switch at the far-end of the D-channel.

Remote capability.

Allow or disallow overlap receiving on a D-channel. Default is NO. Enter carriage return if settings are to be left at default.

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007

Copyright © 2003-2007, Nortel Networks

Page 213
Image 213
Nortel Networks NN43001-301 manual Type Adan, Ctyp Dchi, Cdno, Port, Des, Usr Pri, Ifc, Otbf, Drat, Side NET USR