DTI software implementation 251

LD 73 - Defining the grade of service timers for the DTI card

 

 

 

Prompt

Response

Description

 

 

 

CRC

NC mt dt ct ot

Cyclic redundancy check error counts.

 

 

NC = Error count values are in the range 1-255.

 

 

mt = Maintenance threshold time (MNT).

 

 

dt = No new data calls threshold time (NNDC).

 

 

ct = No new calls threshold time (NNC).

 

 

ot = Out of service threshold time (OOS).

 

 

Note: The following requirements must be met for input.

 

 

mt = Maintenance threshold is equal to or greater than dt.

 

 

dt = Data calls threshold is equal to or greater than ct.

 

 

ct = Calls threshold is equal to or greater than ot.

BPV

NB mt dt ct ot

Bipolar violation error counts.

 

 

NB = Error count values are in the range 1-255.

 

 

mt = Maintenance threshold time (MNT).

 

 

dt = No new data calls threshold time (NNDC).

 

 

ct = No new calls threshold time (NNC).

 

 

ot = Out of service threshold time (OOS).

 

 

Note: The following requirements must be met for this input: mt

 

 

= >dt = >ct = >ot.

FAP

NF mt dt ct ot

Frame alignment problem thresholds.

 

 

NF = Error count values are in the range 1-255.

 

 

mt = Maintenance threshold time (MNT).

 

 

dt = No new data calls threshold time (NNDC).

 

 

ct = No new calls threshold time (NNC).

 

 

ot = Out of service threshold time

 

 

Note: The following requirements must be met for this input: mt

 

 

= >dt = >ct = >ot.

SLP

NS mt dt ct ot

Maintenance threshold slip count.

 

 

NS = Error count values are in the range 1-255.

 

 

mt = Maintenance threshold time (MNT).

 

 

dt = No new data calls threshold time (NNDC).

 

 

ct = No new calls threshold time (NNC).

 

 

ot = Out of service threshold time (OOS).

 

 

 

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007

Copyright © 2003-2007, Nortel Networks

Page 251
Image 251
Nortel Networks NN43001-301 manual LD 73 Defining the grade of service timers for the DTI card, Bpv, Fap, Slp