Nortel Networks NN43001-301 manual Reset alarm counters of all digital cards, Swck

Models: NN43001-301

1 306
Download 306 pages 36.63 Kb
Page 178
Image 178

178Clock Controller description and installation

16Insert the replacement card into the selected slot and hook the locking devices.

17Connect the reference cables (J1 and J2) and the clock-to-clock cable (J3) to the replacement card.

18Set the ENB/DIS switch to ENB on the replacement card.

19Disable the software and enable the card. At the prompt, enter:

LD 60

DID CC x Disable clock controller card, where x=0 or 1

ENL CC x Enable clock controller card, where x=0 or 1

20Verify that the card is active. At the prompt, enter:

SSCK x Get status of system clock, where x=0 or 1

****Exit the overlay

Note: Wait two minutes before proceeding to next step.

21Activate the new card and verify that it is active. At the prompt enter:

LD60

SWCK Switch system clock from active to standby

SSCK x Get status of system clock, where x = 0 or 1

TRCK PCK

Track primary clock, where x = 0 or 1

RCNT

Reset alarm counters of all digital cards

****Exit the overlay

22Set the clock source to the status it was in before the replacement procedure.

23Verify clock switchover and tracking. At the prompt, enter:

SWCK

Switch system clock from active to standby

SSCK x Get status of system clock, where x = 0 or 1

****Exit the overlay

—End—

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007

Copyright © 2003-2007, Nortel Networks

Page 178
Image 178
Nortel Networks NN43001-301 Reset alarm counters of all digital cards, Swck, Switch system clock from active to standby