Nortel Networks NN43001-301 DCH mode and address select switches, OFF Ring line is not grounded

Models: NN43001-301

1 306
Download 306 pages 36.63 Kb
Page 147
Image 147

 

 

NT5D12 switch settings 147

Table 59

 

 

Ring ground switch settings

 

 

 

 

Switch

Description

S2 Switch Setting

 

 

 

1

Trunk 0 Transmit

OFF - Ring line is not grounded

 

 

ON - Ring line is grounded

 

 

 

2

Trunk 0 Receive

OFF - Ring line is not grounded

 

 

ON - Ring line is grounded

 

 

 

3

Trunk 1 Transmit

OFF - Ring line is not grounded

 

 

ON - Ring line is grounded

 

 

 

4

Trunk 1 Receive

OFF - Ring line is not grounded

 

 

ON - Ring line is grounded

 

 

 

DCH mode and address select switches

A set of eight DIP switches selects between an onboard NTBK51AA D-channel daughterboard and an external MSDL/DCHI card. In the case of an onboard NTBK51AA D-channel daughterboard, four of the switches provide the daughterboard address. See Table 60 "DCH mode and address select switch settings" (page 147).

Table 60

DCH mode and address select switch settings

Switch

Description

S3 Switch Setting

 

 

 

1-4

D-channel daughterb

See Table 61 "NTBK51AA daughterboard

 

oard

address select switch settings" (page 148)

 

Address

 

 

 

 

5-7

For future use.

OFF

 

 

 

8

External DCH or

OFF - MSDL or DCHI card

 

Onboard DDCH

ON - Onboard DDCH daughterboard

 

 

 

 

 

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007

Copyright © 2003-2007, Nortel Networks

Page 147
Image 147
Nortel Networks NN43001-301 DCH mode and address select switches, OFF Ring line is not grounded, OFF Msdl or Dchi card