Nortel Networks NN43001-301 manual Port address switch settings, SW3 SW4, Off

Models: NN43001-301

1 306
Download 306 pages 36.63 Kb
Page 89
Image 89

Install the QPC757 DCH 89

Figure 39

QPC757 option and PRI/ISL low-speed programming switch settings

Port address switch settings

Table 27 "D-channel port address switch settings for PRI" (page 89) shows the port address switch settings that apply to SW1, SW2 (the D-channel port), SW3, and SW4.

Table 27

D-channel port address switch settings for PRI

 

 

 

 

Port Address Switch Settings

 

 

Port Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J1

 

J2

SW1

 

SW2

SW3

 

SW4

 

 

 

 

 

 

 

 

 

0

 

1

Off

 

Off

Off

 

Off

 

 

 

 

 

 

 

 

 

2

 

2

Off

 

Off

On

 

Off

 

 

 

 

 

 

 

 

 

4

 

5

Off

 

On

Off

 

Off

 

 

 

 

 

 

 

 

 

6

 

7

Off

 

On

On

 

Off

 

 

 

 

 

 

 

 

 

8

 

9

On

 

Off

Off

 

Off

 

 

 

 

 

 

 

 

 

10

 

11

On

 

Off

On

 

Off

 

 

 

 

 

 

 

 

 

12

 

13

On

 

On

Off

 

Off

 

 

 

 

 

 

 

 

 

14

 

15

On

 

On

On

 

Off

 

 

 

 

 

 

 

 

 

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007

Copyright © 2003-2007, Nortel Networks

Page 89
Image 89
Nortel Networks NN43001-301 manual Port address switch settings, SW3 SW4, Off