Nortel Networks NN43001-301 manual Ccgd, CHG Type RDB

Models: NN43001-301

1 306
Download 306 pages 36.63 Kb
Page 253
Image 253

 

 

DTI software implementation 253

 

 

 

Prompt

Response

Description

 

 

 

PREF CC1

xx

Primary Reference DTI/PRI loop for Clock controller one.

SREF CC1

xx

Primary Reference DTI/PRI loop for Clock controller one.

CC2

xx

Card number for Clock Controller 2.

PREF CC2

xx

Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the

 

 

primary clock reference.

SREF CC2

xx

Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the

 

 

primary clock reference.

CC3

xx

Card number for Clock Controller 3.

PREF CC3

xx

Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the

 

 

primary clock reference.

SREF CC3

xx

Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the

 

 

primary clock reference.

CC4

xx

Card number for Clock Controller 4.

PREF CC4

xx

Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the

 

 

primary clock reference.

CCGD

0-(15)-1440

Clock controller free run guard time in minutes.

CCAR

0-(15)

Clock controller audit rate. The time, in minutes, between normal

 

 

CC audits. Only programmable on units equipped with 2-Mb DTI.

 

 

Note 1: The clock controller prompts only appear for clocks

 

 

which are valid for the machine type being configured. The

 

 

prompts only appear if the system is in a valid state for the

 

 

definition of the 2.0 Mb DTI clock controller data that is, the DTI

 

 

clock references must be unused or in a free-run mode.

 

 

Note 2: Before programming clock controller references, the

 

 

QPC775 clock controller card(s) must be plugged in, and the

 

 

switches on the system’s QPC441 3 Port Extender must be

 

 

appropriately set. Otherwise, the PREF and SREF prompts are

 

 

not given.

 

 

 

LD 16 - Configuring the service routes

Prompt

Response

Description

 

 

 

REQ

NEW

Add or Change Route data block.

 

CHG

 

TYPE

RDB

Route data block.

CUST

xx

Customer number, as defined in LD 15

 

 

 

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007

Copyright © 2003-2007, Nortel Networks

Page 253
Image 253
Nortel Networks NN43001-301 manual Ccgd, CHG Type RDB