Nortel Networks NN43001-301 Install NT8D72 and QPC720 PRI cards on Large Systems, Half Group

Models: NN43001-301

1 306
Download 306 pages 36.63 Kb
Page 123
Image 123

Install NT8D72 and QPC720 PRI cards on Large Systems 123

Install NT8D72 and QPC720 PRI cards on Large Systems

Use Procedure 11 "Install the NT8D72 and QPC720 PRI on Large Systems" (page 123) to install the NT8D72 and QPC720 PRI cards on Large Systems.

Procedure 11

Install the NT8D72 and QPC720 PRI on Large Systems

Step Action

1Determine the cabinet and shelf location of the circuit card to be installed. The following slots can be used if they are not required for other cards.

Table 34

Shelf and slot location of NT8D72 and QPC720 for Half Group and Single Group systems

System

Shelf

Slot

 

 

 

Half Group,

NT6D39 CPU/NET

3–8 Note 1

Single Group

 

18 Note 3

 

 

 

 

NT8D35 DTI Exp Cube

2–3 Note 1

 

 

5–14 Note 1

 

 

 

 

NT8D47 RPE Cube

1, 11, 12

 

 

 

Multi Group

Core

0-3

 

 

 

 

Network Module

5–10,

 

 

13–14

 

 

 

Note 1: DTI/PRI packs require two slots. The slot indicated is the maximum slot that the pack

resides in. For example, the slot 14 pack uses slots 13 and 14.

 

Note 2: The DTI/PRI pack cannot be installed in slot 11. The pack would come in contact with the

BTU installed between slots 11 and 12.

 

Note 3: Slot 18 is only available on CPU shelf, which has no MDU/FDU.

Note 4: DTI/PRI pack could reside in slots 10 and 11, but cannot reside in slots 11 and 12 because

of powering restrictions.

 

 

 

 

 

2Unpack and inspect the PRI cards.

3Set the option switches on the PRI circuit cards.

4Install the PRI circuit card in the assigned shelf and slot.

5Install the network circuit card (if no network loop connection is available).

6If required, install I/O adapters in the I/O panel.

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007

Copyright © 2003-2007, Nortel Networks

Page 123
Image 123
Nortel Networks NN43001-301 manual Install NT8D72 and QPC720 PRI cards on Large Systems, Half Group, NT6D39 CPU/NET