ISL hardware installation 287

Table 104

 

 

 

 

NTAK02 switch settings

 

 

 

 

 

 

 

 

 

Port 0

Port 1

SW1-1

 

SW1-2

 

 

 

 

 

SDI

DCH

OFF

 

OFF

 

 

 

 

 

SDI

DPNSS1

OFF

 

ON

 

 

 

 

 

ESDI

ON

 

ON

 

 

 

 

 

 

 

 

 

 

Port 2

Port 3

SW1-3

 

SW1-4

 

 

 

 

 

SDI

DCH

OFF

 

OFF

 

 

 

 

 

SDI

DPNSS1

OFF

 

ON

 

 

 

 

 

ESDI

ON

 

ON

 

 

 

 

 

Table 105

NTAK02 jumper settings

 

Jumper

Strap for

Strap for

Jumper

 

 

Unit

location

DTE

DCE

location

RS422

RS232

 

 

 

 

 

 

 

Unit 0

J10

C - B

B - A

 

 

 

 

 

 

 

 

 

 

Unit 1

J7

C - B

B - A

J9

C - B

B - A

 

J6

C - B

B - A

J8

C - B

B - A

 

 

 

 

 

 

 

Unit 2

J5

C - B

B - A

 

 

 

 

 

 

 

 

 

 

Unit 3

J4

C - B

B - A

J2

C - B

B - A

 

J3

C - B

B - A

J1

C - B

B - A

 

 

 

 

 

 

 

—End—

Procedure 43

Setting up the D-channel

Step Action

1If this is a dedicated mode installation using leased line modems, the D-channel connects the DCHI with the far-end modem over a dedicated leased line. Synchronous modems with a minimum 2400 baud data rate must be configured. Modems must support leased line capability and synchronous mode. The Hayes Smartmodem 2400 cannot be used on leased lines.

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007