Nortel Networks NN43001-301 manual Procedure Installing ISL hardware, NTAK02 switch setting Port

Models: NN43001-301

1 306
Download 306 pages 36.63 Kb
Page 230
Image 230

2301.5 Mb ISL implementation

The NTAK02 connects to a modem via the NTAK19BA four-port cable. Only ports 1 and 3 are available for use as DCHIs.

Procedure 37

Installing ISL hardware

Step Action

1Set option switches/jumpers on the NTAK02 card as shown in Table 82 "NTAK02 switch setting" (page 230) and Table 83 "NTAK02 jumper settings" (page 230) for mode of operation (RS232 or RS422 and DTE or DCE.)

Table 82

NTAK02 switch setting

Port 0

Port 1

SW 1-1

SW 1-2

 

 

 

 

SDI

DCH

OFF

OFF

 

 

 

 

SDI

DPNSS

OFF

ON

 

 

 

 

ESDI

ON

ON

 

 

 

 

Port 2

 

Port 3

SW 1-3

SW 1-4

 

 

 

 

 

 

SDI

DCH

OFF

OFF

SDI

DPNSS

OFF

ON

ESDI

ON

ON

 

 

 

 

 

Table 83

 

 

 

NTAK02 jumper settings

 

 

 

 

 

 

 

 

Unit

Jumper location

Strap for DTE

Strap for DCE

Unit 0

J10

C - B

B - A

Unit 1

J7

C - B

B - A

 

 

 

J6

C - B

B - A

Unit 2

J5

C - B

B - A

Unit 3

J4

C - B

B - A

 

 

 

J3

C - B

B - A

 

 

 

 

 

 

 

 

 

 

Unit

 

Jumper location

RS422

RS232

 

 

 

 

 

Unit 0

 

 

 

 

 

 

Unit 1

 

J9

C - B

B - A

 

 

 

J8

C - B

B - A

 

 

 

 

 

 

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007

Copyright © 2003-2007, Nortel Networks

Page 230