Nortel Networks NN43001-301 manual LD 73 Defining PRI parameters and thresholds, Mff Aff Crc

Models: NN43001-301

1 306
Download 306 pages 36.63 Kb
Page 278
Image 278

2782.0 Mb PRI implementation

Prompt

Response

Description

 

 

 

PREF CC3

xx

Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the

 

 

primary clock reference.

SREF CC3

xx

Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the

 

 

primary clock reference.

CC4

xx

Card number for Clock Controller 4.

PREF CC4

xx

Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the

 

 

primary clock reference.

SREF CC4

xx

Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the

 

 

primary clock reference.

CCAR

0-(15)

Clock Controller Audit Rate. Enter the time (in minutes) between

 

 

normal CC audits.

 

 

 

LD 73 - Defining PRI parameters and thresholds

 

 

 

Prompt

Response

Description

 

 

 

REQ

CHG

Change data.

TYPE

PRI2

2.0 Mb PRI.

FEAT

LPTI

Loop timers.

LOOP

X

X is the slot number of the 2.0 Mb PRI card.

MFF

AFF (CRC)

Alternate mode or CRC multiframe mode.

ALRM

(REG) ALT

Default or alternate alarms selected.

G10S

 

 

SLP

mc mt oc ot

Slip error count.

 

 

where

 

 

mc = Maintenance threshold slip count, 1- (5)-255.

 

 

mt = Maintenance threshold time, default 24 hours.

 

 

oc = Out-of-service threshold slip count, 1-(30)-255.

 

 

ot = Out-of-service threshold time, default 1 hour.

BPV

n1 n2

Bipolar violation error count. Range is 1-(128)-255 for n1,

 

 

1-(122)-255 for n2.

 

 

where

 

 

n1 is multiplied by 16 to obtain the actual count, giving an

 

 

actual count range of 16-4080.

 

 

 

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007

Copyright © 2003-2007, Nortel Networks

Page 278
Image 278
Nortel Networks NN43001-301 manual LD 73 Defining PRI parameters and thresholds, Mff Aff Crc, Alrm REG ALT