138NT5D97 Dual-port DTI2/PRI2 installation and removal

Table 52

NTBK51AA DCH switches for NT5D97AD

Switch number

Function

 

 

S9_1-4

DCH daughter card address

 

 

S9_5-8

Set to OFF

 

 

S9_9

Set to ON (NTBK51AA Mode)

 

 

S9_10

Set to ON (NTBK51AA Mode)

 

 

MSDL external card

Table 53 "Switch settings for MSDL external card" (page 138) lists the switch numbers assigned for future use on the MSDL external card.

Table 53

Switch settings for MSDL external card

Switch number

Function

 

 

S9_1-10

For future use

 

 

S8_1-10

For future use

 

 

Use Table 54 "Switch setting for MSDL external card" (page 138) to set the card address.

Table 54

Switch setting for MSDL external card

 

 

 

Switch Setting

 

 

 

 

 

 

 

DNUM (LD 17)

1

2

 

3

4

 

 

 

 

 

 

0

OFF

OFF

 

OFF

OFF

 

 

 

 

 

 

1

ON

OFF

 

OFF

OFF

 

 

 

 

 

 

2

OFF

ON

 

OFF

OFF

 

 

 

 

 

 

3

ON

ON

 

OFF

OFF

 

 

 

 

 

 

4

OFF

OFF

 

ON

OFF

 

 

 

 

 

 

5

ON

OFF

 

ON

OFF

 

 

 

 

 

 

6

OFF

ON

 

ON

OFF

 

 

 

 

 

 

7

ON

ON

 

ON

OFF

 

 

 

 

 

 

8

OFF

OFF

 

OFF

ON

 

 

 

 

 

 

9

ON

OFF

 

OFF

ON

 

 

 

 

 

 

10

OFF

ON

 

OFF

ON

 

 

 

 

 

 

11

ON

ON

 

OFF

ON

 

 

 

 

 

 

12

OFF

OFF

 

ON

ON

 

 

 

 

 

 

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007

Copyright © 2003-2007, Nortel Networks

Page 138
Image 138