Nortel Networks NN43001-301 manual Configure the NT5D97 DDP2

Models: NN43001-301

1 306
Download 306 pages 36.63 Kb
Page 141
Image 141

Configure the NT5D97 DDP2 141

Procedure 15

Remove the NT5D97 from Large Systems

Step Action

1Determine the cabinet and shelf location of the NT5D97 card to be removed.

2Disable the Network Loop using LD 60. The command is DISL "loop number."

The associated DCHI might have to be disabled first. The faceplate switch ENB/DIS should not be disabled until both PRI2/DTI2 loops are disabled first.

3Remove data from memory, if the NT5D97 card is being completely removed, not replaced.

4Remove cross connections at the MDF to wall-mounted crossconnect terminal.

5Tag and disconnect cables from the card.

6Rearrange Clock Controller cables if required.

CAUTION

Clock Controller cables connecting the Clock Controller and DDP2 card must NOT be routed through the center of the cabinet past the power harness. Instead, they should be routed around the outside of the equipment shelves.

7Remove the DDP2 card only if both loops are disabled. If the other circuit of a DDP2 card is in use, DO NOT remove the card. The Faceplate switch ENB/DIS must be in the OFF (DIS) position before the card is removed, otherwise the system will initialize.

8Pack and store the NT5D97 card and circuit card.

—End—

Configure the NT5D97 DDP2

After the NT5D97 DDP2 is installed, configure the system using the same procedures as the standard NT8D72BA PRI2.

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007

Copyright © 2003-2007, Nortel Networks

Page 141
Image 141
Nortel Networks NN43001-301 manual Configure the NT5D97 DDP2, Procedure Remove the NT5D97 from Large Systems