Nortel Networks NN43001-301 PRI to Echo canceller pin assignments, Electromagnetic Interference

Models: NN43001-301

1 306
Download 306 pages 36.63 Kb
Page 192
Image 192

192Echo canceller installation

Canceller only: OFF

H reset: OFF

H hold: OFF

PRI to Echo canceller pin assignments

The echo canceller is controlled by an RS-232 port on the PRI circuit pack. The following tables give the echo canceller pin assignments, operating parameters and initialization procedures.

See Table 70 "PRI-to-Echo canceller - pin assignments" (page 192) for PRI-to-Echo canceller pin assignments; refer to Figure 75 "PRI to echo canceller cabling" (page 193) for a PRI-to-Echo-canceller cabling schematic.

Table 70

PRI-to-Echo canceller - pin assignments

 

 

 

EIA RS-232-C

 

 

Echo canceller

circuit

Signal

PRI pin

pin

designator

 

 

 

 

TXD

5

2

BA

(Transmitted Data)

 

 

 

 

 

 

 

RXD

2

3

BB

(Received Data)

 

 

 

 

 

 

 

RTS

4

CC

(Request to Send)

 

 

 

 

 

 

 

CTS

5

CB

(Clear to Send)

 

 

 

 

 

 

 

Common Return

10

7

AB

(signal ground)

 

 

 

 

 

 

 

DCD

1

8

CF

(received line signal detector)

 

 

 

 

 

 

 

DTR

4

20

CD

(data terminal ready)

 

 

 

 

 

 

 

Electromagnetic Interference

The Electromagnetic Interference (EMI) filter assembly for PRI is PO643763. The system meets FCC Part 15, Subpart J, Class A requirements regarding EMI. In order to accomplish this, the SDI cables must exit the cabinet through EMI filters on the I/O panel. This procedure depends on the system cabinet type.

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301 02.03 Standard

Release 5.5 7 December 2007

Copyright © 2003-2007, Nortel Networks

Page 192
Image 192
Nortel Networks NN43001-301 manual PRI to Echo canceller pin assignments, Electromagnetic Interference