134NT5D97 Dual-port DTI2/PRI2 installation and removal

NT5D97AD DIP switch settings

The NT5D97 DDP2 card is equipped with 6x2 sets of DIP switches for trunk parameters settings for port 0 and port 1 respectively. Additionally, the DDP2 card is equipped with one set of four DIP switches for the Ring Ground setting. The NT5D97AA/AB has one set of eight DIP switches and NT5D97AD has two sets of ten DIP switches for the D-channel Handler parameters setting.

The DIP switches are used for the setting of default values of certain parameters. Firmware reads the general purpose switches, which sets the default values accordingly

Table 45

DIP switch settings for NT5D97AD

 

Card

Trunks

Port 0

 

Port 1 Trunk 0

Trunk 1

 

0 and 1

 

 

 

 

 

 

 

 

 

ENB/DSB mounted on the face

S1

 

 

 

 

 

 

plate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ring Ground

 

S16

 

 

 

 

 

 

 

 

 

 

 

 

 

DPNSS

 

 

S8

 

S9

 

 

 

 

 

 

 

 

 

 

MSDL

 

 

 

S9

 

 

 

 

 

 

 

 

 

 

TX Mode

 

 

 

 

 

S2

S10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S3

S13

 

 

 

 

 

 

 

 

LBO Setting

 

 

 

 

 

S4

S14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S5

S15

 

 

 

 

 

 

 

 

Receiver Interface

 

 

 

 

 

S6

S11

 

 

 

 

 

 

 

 

General Purpose

 

 

 

 

 

S12

S7

 

 

 

 

 

 

 

 

Refer to DIP switch locations in Figure 56 "Dip switches locations for

NT5D97AD" (page 135).