Set the switches on the circuit card according to the requirements of your specific installation:

Switch SW1 - DCHI configuration

This switch enables and disables the onboard DCHI and sets the operating mode of the DCHI.

For the U.K., use DPNSS1 mode. For all other countries, use Q.931 mode.

Table 92

Switch SW1

Switch

Down (On)

Up (Off)

 

 

 

SW 1-1

enable DCHI

disable DCHI

 

 

 

SW 1-2

DPNSS1/DASS2

Q.931

 

 

 

Switch SW2 - Carrier impedance configuration

This switch sets the carrier impedance to either 1201/2 or 751/2. Twisted pair cable is usually associated with 1201/2. Coaxial cable is usually associated with the 751/2 setting.

Table 93

Switch SW2

Cable Type

SW 2-1

SW 2-2

 

 

 

751/2

Up (Off)

Down (On)

 

 

 

1201/2

Down (On)

Up (Off)

 

 

 

Switch SW3 - Clock controller configuration

This switch enables and hardware disables the onboard Clock Controller. SW 3-2 should be disabled if the onboard clock controller is not in use.

Table 94

Switch SW3

Switch

Down (On)

Up (Off)

Note

 

 

 

 

SW 3-1

Spare

 

 

 

 

SW 3-2

Disabled

Enabled

 

 

 

 

 

Switch SW4 - Carrier shield grounding

This switch allows for the selective grounding of the Tx/Rx pairs of the carrier cable. Closing the switch (down position) applies Frame Ground (FGND) to the coaxial carrier cable shield, creating a 751/2 unbalanced configuration. This applies only to the NTBK05CA cable.