PRI software implementation 275

 

 

 

 

Prompt

Response

 

Description

 

 

 

 

RLS

XX

 

Software release of far-end. This is the current software release

 

 

 

of the far-end. If the far-end has an incompatible release of

 

 

 

software, it prevents the sending of application messages, for

 

 

 

example, ’Network Ring Again.

RCAP

MSL

 

MSDL RCAP capability.

OVLR

<CR>

 

Allow or disallow overlap receiving on a D-channel. Default is

 

 

 

NO.

LAPD

YES (NO)

 

Change LAPD parameters. Enter carriage return if timers are

 

 

 

left at default. The following timers are prompted only if LAPD is

 

 

 

set to YES. They are all left at default during initial setup.

- T23

1-(20)-31

 

Interface guard timer checks how long the interface takes to

 

 

 

respond. In units of 0.5 seconds (default 20 = 10 seconds).

T200

2-(3)-40

 

Retransmission timer in units of 0.5 seconds (default 3 = 1.5

 

 

 

seconds).

- N200

1-(3)-8

 

Maximum number of retransmissions.

- N201

4(260)

 

Maximum number of octets in information field.

- K

1-(7)-32

 

Maximum number of outstanding unacknowledged frames

 

 

 

(NAKS).

 

 

 

 

LD 15 - Defining a PRI customer

 

 

 

 

 

 

Prompt

Response

 

Description

 

 

 

 

REQ:

NEW

 

Add new data.

 

CHG

 

Change existing data.

TYPE:

NET

 

Networking data.

CUST

0-99

 

Customer number

 

 

 

Range for Large System, Call Server 1000E, and

 

 

 

Media Gateway 1000E

 

0-31

 

Range for Small System, Media Gateway 1000B

LDN

XXXX

 

Enter the customer’s Listed Directory Number.

AC2

 

 

Access Code 2. Enter call types (type of number) that use

 

 

 

access code 2. Multiple responses are permitted. This prompt

 

 

 

only appears on NARS equipped systems. If a call type is not

 

 

 

entered here, it automatically defaults to access code 1.

 

NPA

 

E.164 National.

 

NXX

 

E.164 Subscriber.

 

INTL

 

International.

 

SPN

 

Special Number.

 

LOC

 

Location Code.

ISDN

YES

 

Customer is equipped with ISDN.

 

 

 

 

 

 