9Connect one end of a 1 meter jumper cable to the Channel 0 connector on the lower or left side I/O Interface card in the master cabinet.
10Connect the other end of the 1 meter jumper cable to the Channel 0 connector on the lower or left side
11Connect one end of a second 3 meter data cable to the Channel #2 connector on the RAID Controller (or the Channel #1 connector of a second single channel RAID Controller).
12Connect the other end of the data cable to the Channel 1 connector on the upper or right side two- channel Ultra Extender card.
13Connect one end of a second 1 meter jumper cable to the Channel 1 connector on the lower or left side I/O Interface card in the master cabinet.
14Connect the other end of the second 1 meter jumper cable to the Channel 1 connector on the lower or left side
Note: SCSI termination is automatic and requires no user configuration
15Power on the DEU subsystems. After the
16Access the Options menu on the Operator Control Panel and choose the SAFTE CHAIN ID selection. Set the cabinet identities of the master and slave subsystems. Refer to “SAFTE CHAIN ID” described earlier in this Guide.
17After setting the cabinet identifications you must power cycle the subsystems. Observe normal power cycling precautions by waiting a minimum of five seconds before adding power again.
This will reset the SCSI IDs to a default setting that prevents a SCSI ID conflict under normal conditions, refer to “Default Configurations” later in this section.
18Power up your computer system and run the configuration program.
PRINTER NOTE: Page size 9” x 9.25”. Align this page to top, right hand corner. Back box bleeds off top and right edge. Left side of page extends to 9.25 inches.