SET LOWER SLOT IDS

 

 

 

 

SET UPPER SLOT IDS

 

 

 

 

SET RAID MODULE ID

 

 

 

 

SET SAFTE ID

0

1

2

3

LOWER 4

0

1

2

4

 

4

5

6

7

 

4

5

6

8

 

5

6

7

8

MENU ENTER ESCAPE

MENU ENTER ESCAPE

Reset Default IDs Selection

Choosing the “Reset Default Ids” option will automatically set the SCSI IDs to IDs 0, 1, 2, and 4 for the drives, and ID 3 for the processor. SCSI ID values for the drives will be the same for both SCSI bus channels.

If an Ultra S2S RAID Controller is installed the SCSI

ID will automatically be set to ID # 0.

SET UPPER SLOT IDS

SET RAID MODULE ID

SET SAFTE ID

RESET DEFAULT IDS

ALL SCSI IDS SET

TO DUAL-BUS MODE (CYCLE POWER TO EFFECT CHANGES)

MENU ENTER ESCAPE

MENU ENTER ESCAPE

Note: When the “Reset Default Ids” is selected or anytime you change a SCSI ID setting, you must power the DEU OFF and ON at that screen for those settings to take effect. Be sure to power OFF the host computer prior to cycling the power on the DEU. Otherwise, the PCI RAID Controller (if used) will “kill” all drives in the array.

PRINTER NOTE: Page size 9” x 9.25”. Align this page to top, right hand corner. Back box bleeds off top and right edge. Left side of page extends to 9.25 inches.