Single-Bus Cabinet Configuration
Ultra SCSI | Ch 1 |
Controller |
Host Computer
meter)(1
Ultra SCSIWide CableData
TOP |
|
Ch 0 | Ch 1 |
| I/O Interface |
| Card |
| I/O Interface |
| Card |
Ch 0 | Ch 1 |
Note: SCSI termination in the DEU is automatic and requires no user configuration. Refer to “Cabling Configuration” described earlier for information on systems using DEC Fault bus protocol.
3Turn on the power to the DEU. After the
4Access the Options menu on the Operator Control Panel and choose the SAFTE CHAIN ID selection. Choose the “None” selection, refer to “SAFTE CHAIN ID” described later in this guide.
5After setting the cabinet identifications you must power cycle the subsystem. Observe normal power cycling precautions by waiting a minimum of five (5) seconds before adding power again.
This will reset the SCSI IDs to a default setting that prevents a SCSI ID conflict under normal conditions.
6Power up your computer system and run the configuration program.
This completes the hardware installation.
Note: For additional configuration options using Ultra
Wide SCSI, refer to Appendix D.