JP5 (SCA Remote/Delay Start)

Caution: Jumper configuration to be performed by qualified service personnel only.

The spin-up of the drive slots is determined by adding jumpers to JP5. JP5 is a two position dual-row header. Position 1 & 2 control the “Delayed_Start” signal and position 3 & 4 control the “Remote_Start” signal.

4 3

2 1

REMOTE DELAY

JP5

Pins 1 and 2

Pins 3 and 4

Drive Spinup Mode

 

 

 

ON

ON

Motor spins up only on SCSI “start”

 

 

commands.

 

 

 

ON

OFF

Motor spins up after a delay of 12

 

 

(may vary depending on drive type)

 

 

seconds times the numeric SCSI ID

 

 

setting of the associated drive.

 

 

 

OFF

ON

Motor spins up only on SCSI “start”

 

 

commands.

 

 

 

OFF

OFF

Motor spins up at DC power on.

 

 

 