The I/O Interface card incorporates
Two sets of jumpers are provided on the card. One set routes Term Power in the event that the host controller is not providing it.
The next set of jumpers addresses a specific set of controllers that use the DEC Fault Bus protocol. If you are using a DEC system where the controller uses this protocol, you will need to jumper locations (jumper on both pins) JP3 and JP4 for each channel that has an external SCSI cable connected. This will disable termination at that point.
If you are using a standard host adapter that provides Term Power, no change is required and SCSI bus termination will occur automatically.
Power Cord Connector and Fuse
The power cord connector supplies the AC power to the DEU through a power cord connected to a conventional
Internal Components
There are seven primary internal components: disk drives (up to eight), Fault LEDs, power switch,