Packard Bell ST8000, 5800 manual

Models: ST8000 5800

1 127
Download 127 pages 8.6 Kb
Page 118
Image 118

10Connect one end of a 1 meter jumper cable to the Channel 0 connector on the upper or right side I/O Interface card in the master cabinet.

11Connect the other end of the 1 meter jumper cable to the Channel 1 connector on the upper or right side

1-channel Ultra Extender card installed in the slave #2 cabinet.

12Connect one end of the second 25 meter data cable to the Channel #2 connector on the differential host adapter.

13Connect the other end of the data cable to the Channel 1 connector on the lower or left side 2- channel Differential Converter card.

14Connect one end of a second 1 meter jumper cable to the Channel 1 connector on the upper or right side I/O Interface card in the master cabinet.

15Connect the other end of the second 1 meter jumper cable to the Channel 1 connector on the upper or right side 1-channel Ultra Extender card installed in the slave #1 cabinet.

Note: SCSI termination is automatic and requires no user configuration.

16Turn on the power to the DEU.

17After the power-on self-test has completed, HDD Status and Channel Mode LEDs will be solid green.

18Access the Options menu on the Operator Control Panel and choose the SAFTE CHAIN ID selection. Refer to “SAFTE CHAIN ID” earlier in this Guide.

19After setting the cabinet identifications you must power cycle the subsystems. Observe normal power cycling precautions by waiting a minimum of five seconds before adding power again.

This will reset the SCSI IDs to a default setting that prevents a SCSI ID conflict under normal conditions, refer to “Default Configurations” later in this section.

20Power up your computer system and run the configuration program.

This completes the setup and configuration.

PRINTER NOTE: Page size 9” x 9.25”. Align this page to top, right hand corner. Back box bleeds off top and right edge. Left side of page extends to 9.25 inches.

Page 118
Image 118
Packard Bell ST8000, 5800 manual