3.5.1.6 Reset to Factory Setting
The original values of all converter parameters can be restored with a reset to the factory setting by
means of P0970.
These values are indicated in the List Manual with "Factory Setting".
Note
When resetting the parameters to the factory setting, the data transmission memory is reinitialized.
That means that data transmission is interrupted while the reset takes place.
Note
The following parameters remain unchanged when a reset to factory values is performed:
P0014 memory mode
P0100 Europe/North America
P0201 Power stack code number
Communication parameters (USS and PROFIBUS and PROFINET settings)
Data depending on the power module