Chapter 7. PARAMETER SETUP

PID parameter settings “P I d

No.

Item Code

Item

Factory

User

 

 

Setting

 

 

 

 

 

 

 

Setting

Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

P -1

Proportional band

100.0

 

P

:

0.0 to 999.9% (0D, 6D output models)

 

 

 

 

(PID set 1)

 

 

 

 

0.0 enables ON-OFF control.

 

 

 

 

2

1 -1

Reset time

0

 

 

 

0.1 to 999.9% (models other than 0D and 6D output

 

 

(PID set 1)

 

 

 

 

models)

 

 

 

 

3

D -1

Rate time

0

 

I

:

0 to 3600s

 

 

 

 

 

 

(PID set 1)

 

 

 

 

0 disables integrating action.

 

 

 

 

4

O L -1

MV lower limit

0.0

 

D

:

0 to 1200s

 

 

 

 

 

 

(PID set 1)

 

 

 

 

0 disables derivative action.

 

 

 

 

5

O H -1

MV upper limit

100.0

 

O L : -10.0 to MV upper limit %

 

 

 

 

 

 

(PID set 1)

 

 

O H : MV lower limit to 110.0%

 

 

 

 

6

R E -1

Manual reset

50.0

 

R E :

0.0 to 100.0%

 

 

 

 

 

 

(PID set 1)

 

 

B R :

0 to 30

 

 

 

 

7

D R -1

Brake

0

 

 

 

0 disables the brake function.

 

 

 

 

 

 

(PID set 1)

 

 

D P :

0.1 to 999.9%

 

 

 

 

8

D P -1

Disturbance inhibit

100.0

 

D 1

:

1 to 3600s

 

 

 

 

 

 

proportional band

 

 

D D :

0 to 1200

 

 

 

 

 

 

(PID set 1)

 

 

 

 

0 disables derivative action.

 

 

 

 

9

D 1 -1

Disturbance inhibit

120

 

 

 

 

 

 

 

 

 

 

reset time

 

 

[Note]

 

 

 

 

 

 

 

(PID set 1)

 

 

On 0D and 6D output models, when P setting is 0.0,

10

D D -1

Disturbance inhibit

0

 

 

ON-OFF control is enabled. “– – – –” is displayed for

 

 

rate time

 

 

 

items I, D, O L, O H, R E, D P, D I and

D D, and

 

 

(PID set 1)

 

 

 

setting is not possible.

 

 

 

 

11

P -2

Proportional band

100.0

 

When variable parameter M . -Csetting is 2 (estimated

 

 

(PID set 2)

 

 

 

 

 

 

 

position control only) on 2G output models,

 

 

12

1 -2

Reset time

0

 

 

 

 

 

 

 

“– – – –” is displayed for items O L and O H, and

 

 

(PID set 2)

 

 

 

setting is not possible.

 

 

 

 

13

D -2

Rate time

0

 

When I setting is not 0, “– – – –” is displayed for R E

 

 

(PID set 2)

 

 

 

 

 

 

 

and setting is not possible.

 

 

 

 

14

O L -2

MV lower limit

0.0

 

 

 

 

 

 

 

When variable parameter S T setting is 0 (smart-tuning

 

 

(PID set 2)

 

 

 

 

 

 

 

disabled), “– – – –” is displayed for B R and setting is

15

O H -2

MV upper limit

100.0

 

 

 

 

not possible.

 

 

 

 

 

 

(PID set 2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

R E -2

Manual reset

50.0

 

When variable parameter 2 P 1 D setting is 0 (2

 

 

(PID set 2)

 

 

 

degrees of freedom PID disabled), the items for

17

B R -2

Brake

0

 

 

D P, D 1, D D are not displayed.

 

 

 

 

 

 

(PID set 2)

 

 

On heat/cool models, the set No. of the PID parameter

18

D P -2

Disturbance inhibit

100.0

 

 

 

used for the PID set No. is as follows:

 

 

 

 

 

proportional band

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(PID set 2)

 

 

 

PID Set No. Designated in the

PID Set

PID Set

 

19

D I -2

Disturbance inhibit

120

 

 

Program or Zone No. According

 

 

 

(heat)

(cool)

 

 

 

reset time

 

 

 

to Automatic Selection of PID Set

 

 

 

 

 

 

 

 

 

 

 

 

(PID set 2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

1

2

 

20

D D -2

Disturbance inhibit

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

3

4

 

 

 

rate time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(PID set 2)

 

 

 

 

3

 

5

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7-23

Page 108
Image 108
Sonic Alert DCP301 user manual PID parameter settings P I d, PID Set