Chapter 11. CALIBRATION

11-2 Calibration Procedures

Enter calibration mode

(1)Release keylock. (PARA LoC=0 and PrtC=0)

(2)Press DISP key to permit ordinary indication condition.

Change to READY (RUN and HLD are off) and AUTO (MAN off) modes. The following LEDs will illuminate after the above operations.

RUN LED is OFF HLD LED is OFF MAN LED is OFF

PROG Display

(Program No. Display)

SEG Display

(Segment No. Display)

PROG SEG PV

SP OUT

RUN

TM

 

 

 

 

HLD

CYC

 

 

 

 

CH1

 

 

 

 

MAN

 

 

 

 

CH2

 

 

 

 

PRG

 

 

 

 

PROFILE

AT

OT1

OT2

OT3

 

BAT

EV1 EV2

EV3 T1

T2

T3

T4

T5

 

PROG

RUN/HOLD

DISP

Upper Display

Lower Display

FUNC A/M PARA CLR

LOADER

AT

ENT

Figure 11-2.

(3)To enter calibration mode, hold down the FUNC key, and press ENT key and key simultaneously.

The display will show the symbols described in Figure 11-3. If the indication is dif- ferent, repeat the above procedure after pushing DISP key to refresh the display.

(4) To select individual calibration items, press , , , or keys to select the item by scrolling, then PARA key, and ENT key.

The order of calibration items is described in Table 11-2.