Chapter 9. TROUBLESHOOTING

Items cannot be changed by pressing in program setup state

Cause

Remedy

 

 

The pattern item has not been set.

Set SP and time data.

 

 

Programming items are set to “display OFF”.

All setup data C 6 8 to C 7 1 settings are “1”. Set

 

necessary items to 0.

 

 

Event items cannot be displayed by repeatedly pressing in program setup state

Cause

Remedy

 

 

Event type is controller status event.

Set event type (E T 1, E T 2, E T 3) in event configura-

 

tion date to one of 0 to 11 or 50.

Programming items are set to “display OFF”.

Set setup data C 6 8 setting to 0.

 

 

Time events cannot be displayed by repeatedly pressing in program setup state

Cause

Remedy

 

 

Time event is assigned to segment No. event.

Change event configuration data T T setting and assign

 

to time event.

 

 

This model does not support time events.

Select a mode that supports time events (option).

 

 

Programming items are set to “display OFF”.

Set setup data C 6 q setting to 0.

 

 

PID set items cannot be displayed by repeatedly pressing in program setup state

Cause

 

Remedy

 

 

 

PID set auto-switching is set to ON.

Set setup data C

1 1 setting to 0.

 

 

 

The controller is set to programmer function

Set setup data C

1 8 setting to 0.

by 5G output.

 

 

3-position control is selected by 3D output.

Set setup data C 4 5 setting in use to 0 and switch to

 

PID control from 3-position control.

 

 

Programming items are set to “display OFF”.

Set setup data C 7 0 setting to 0.

 

 

 

G.Soak items cannot be displayed by repeatedly pressing in program setup state

Cause

Remedy

 

 

Programming items are set to “display OFF”.

Set setup data C 7 0 setting to 0.

 

 

PV start items, cycle items and pattern link items cannot be displayed by repeat-

edly pressing in program setup state

Cause

Remedy

 

 

Programming items are set to “display OFF”.

Set setup data C 7 1 setting to 0.

 

 

9-6