Chapter 10. SPECIFICATIONS

 

Item

 

 

 

Specification

 

 

 

 

 

 

 

 

Display characters

Char. bit count

 

11bits/character

 

 

 

 

Format

 

1 start bit, even parity, 1 stop bit; or 1 start bit, no parity, and 2 stop

 

 

 

 

bits

 

 

 

 

Data length

 

8bits

 

 

 

Isolation

All inputs and outputs are completely isolated.

 

RS-485 communications can be performed by connecting to a computer equipped with an RS-485 interface.

General

Memory backup

Memory

Battery backed-up RAM

Specifica-

 

Battery life

Controller power OFF

Approx. 3 years under standard conditions

tions

 

 

Controller power ON

Approx. 10 years under standard conditions

 

Rated power voltage

90 to 264Vac, 50/60Hz

 

 

 

Power consumption

30VA max.

 

 

 

 

 

Power ON rush current

15A max., 10ms (under operating conditions)

 

Handling Precautions

 

When starting up a number of DCP31s simultaneously, ensure ample power is supplied

 

or stagger startup times. Otherwise, the controllers may not start normally due to inrush

 

current induced-voltage drop. Voltage must stabilize within 2s after power ON.

 

 

 

 

Power ON operation

Reset time:

15s max. (time until normal operation possible under normal operating

 

conditions)

 

 

 

Allowable transient power

20ms max. (under operating conditions)

loss

 

 

 

 

 

 

Insulation resistance

Min. 20MΩ across power terminal (1) or (2) and ground terminal (3) (using a 500Vac

 

megger)

 

 

 

 

 

 

Dielectric strength

1500Vac 50/60Hz for 1min across power terminal and ground terminal

 

1500Vac 50/60Hz for 1min across relay output and ground terminal

 

500Vac 50/60Hz for 1min across non-power terminal and ground terminal

 

500Vac 50/60Hz for 1min across isolated terminals

 

 

 

 

Standard conditions

Ambient temperature

 

23 ±2°C

 

Ambient humidity

 

60 ±5%RH

 

Rated power voltage

 

105Vac ±1%

 

Power frequency

 

50 ±1Hz or 60 ±1Hz

 

Vibration resistance

 

0m/s2

 

Impact resistance

 

0m/s2

 

Mounting angle

 

 

Reference plane (vertical) ±3°

 

Altitude

 

 

2000m max.

Operating conditions

Ambient temperature

 

0 to 50°C (temperature at case bottom when closely mounted)

 

range

 

 

10 to 90%RH (no condensation)

 

Ambient humidity range

 

90 to 264Vac

 

 

 

 

 

Rated power voltage

 

50 ±2Hz or 60 ±2Hz

 

Power frequency

 

0 to 1.96m/s2

 

Vibration resistance

 

0 to 9.80m/s2

 

Impact resistance

 

Reference plane (vertical) ±10°

 

Mounting angle

 

 

 

Installation mode

Permanently connected type controller, indoor installation, panel-mounted

Applicable standards

EN61010-1, EN50081-2, EN50082-2 (CE statement), EN61326

 

 

Installation category

Category II (IEC664-1, EN61010-1)

 

 

 

 

 

Pollution degree

2

 

 

 