4 Replacement Procedures

4.18 Fluorescent Lamp

4.18 Fluorescent Lamp

This system uses LCD modules from the following suppliers. The procedure for replacing the fluorescent lamp is different for each LCD module. Refer to the appropriate procedure.

Type

Part No.

Supplier

Section

 

 

 

 

14.1 inch

G33C00012110

TMD

4.18.1

(XGA)

 

 

 

G33C00013110

TMD

4.18.1

 

 

 

 

 

VF2093P01

CHIMEI

4.18.2

 

 

 

 

 

VF2058P01

Samsung

4.18.3

 

 

 

 

 

VF2048P01

Samsung

4.18.4

 

 

 

 

 

VF2062P01

LG.Philips

4.18.5

 

 

 

 

15.0 inch

G33C0000G110

LG.Philips

4.18.6

(XGA)

 

 

 

G33C0000L110

Samsung

4.18.7

 

 

 

 

 

G33C0000Q110

Sharp

4.18.8

 

 

 

 

 

G33C0000M110

CHIMEI

4.18.9

 

 

 

 

15.0 inch

G33C0000R110

LG.Philips

4.18.10

(SXGA+)

 

 

 

G33C0000N110

Samsung

4.18.11

 

 

 

 

 

G33C0000P110

Sharp

4.18.12

 

 

 

 

NOTE: - When working with a LCD module, always use a flat, grounded table.

(1)Handle the backlight unit in the environment without dust, such as on the clean bench. Keep the worktable free from any screws or other material that may scratch the LCD surface.

(2)Use an anti-static or protective sheet.

(3)When replacing the FL unit, cover with a finger protector or similar to prevent dirtying or scratching the LCD panel.

(4)Take care when handling the lamp. Excessive force may break the lamp.

(5)Take care not to dirty or deform the lamp reflector.

(6)Ensure always that the power of the LCD module is turned off before connecting or disconnecting cables and connectors.