Toshiba A10 manual 1R25-B1V output

Models: A10 A1

1 417
Download 417 pages 5.8 Kb
Page 63
Image 63

2 Troubleshooting Procedures

2.3 Power Supply Troubleshooting

1R25-B1V output

Error code

Meaning

 

 

D0h

1R25-B1V voltage is over 1.50V when the computer is powered on/off.

 

 

D1h

1R25-B1V voltage is 1.063V or less when the computer is powered on.

 

 

D2h

1R25-B1V voltage is 1.063V or less when the computer is booting up.

 

 

D3h

1R25-B1V voltage is 1.063V or more when the computer is powered

 

off.

D4h

1R25-B1V voltage is 1.063V or less when the computer is suspended.

 

 

2R5-B2V output

Error code

Meaning

 

 

C0h

2R5-B2V voltage is over 3.00V when the computer is powered on/off.

 

 

C1h

2R5-B2V voltage is 2.125V or less when the computer is powered on.

 

 

C2h

2R5-B2V voltage is 2.125V or less when the computer is booting up.

 

 

C3h

2R5-B2V voltage is 2.125V or more when the computer is powered off.

 

 

C4h

2R5-B2V voltage is 2.125V or less when the computer is suspended.

 

 

2-12

Satellite A10/TECRA A1/Satellite Pro A10 Maintenance Manual (960-445)

Page 63
Image 63
Toshiba A10 manual 1R25-B1V output