4 Replacement Procedures

4.18 Fluorescent Lamp

7.Bend the TCP attaching to the source board and secure it with two screws. Then bend the TCP attaching to the gate board with two screws and insert the FPC (G) into the connector of the source board.

Do not hold the edge.

Do not hold the edge.

Figure 4-170 Replacing 15.0 Inch Sharp fluorescent lamp (SXGA+) (18)

Check the condition after mating. *Check the condition of the concave portion of

the FPC and the outline of the connector. *Insert the FPC to the end. There shall be no

out of position in θ. *Lock surely the connector.

Fit the pin and the hole.

Screw

Fold the source board.

Poor mating: Failure

Out-of-position in θ: Failure

Screw

Screw

Fit the pin and the hole.

(G)

Fit the pin and the hole.

Screw tightening torque: 0.9kgcm

Do not cover theprojection.

Fold the gate board.

Screw

Figure 4-171 Replacing 15.0 Inch Sharp fluorescent lamp (SXGA+) (19)

4-156

Satellite A10/TECRA A1/Satellite Pro A10 Maintenance Manual (960-445)

Page 363
Image 363
Toshiba A10 manual Replacing 15.0 Inch Sharp fluorescent lamp SXGA+