4.18 Fluorescent Lamp

4 Replacement Procedures

Fasten screws of the PCB and bezel

1.Fasten four screws on the left edge in the order (5), (6), (7), and (8) shown in Figure 4-55.

2.Fasten four screws on the right edge in the order (1), (2), (3), and (4) shown in Figure 4-55.

CAUTION: Fasten the screws in the orders shown in Figure 4-55. No loose fastening is allowed.

The tightening torque must not exceed 0.147N・m (1.5kgfcm) for all the eight screws.

For the Philips screwdrivers, use an insert bit of point size 0.

Fasten the eight M2×2.2

1

2

3

4

5

6

7

8

Figure 4-55 Replacing 14 Inch TMD fluorescent lamp (11)

Satellite A10/TECRA A1/Satellite Pro A10 Maintenance Manual (960-445)

4-75

Page 281
Image 281
Toshiba A10 manual Replacing 14 Inch TMD fluorescent lamp