4.18 Fluorescent Lamp

4 Replacement Procedures

4.18.1 Replacing the TMD 14.1 Inch XGA Fluorescent Lamp

Replace the Toshiba 14.1-inch XGA fluorescent lamp according to the following procedures and Figures 4-45 to 4-56.

4.18.1.1 Disassembling Fluorescent Lamp

Peeling off the tapes and insulation sheets

1.Flip the module over and place it on a flat surface that is free of foreign objects.

2.In the order (1), (2), and (3) shown in Figure 4-45, remove the tape for fixing the FL tube cable, two pieces of tape on the bezel that are close to the FL tube, and the X- PCB insulation sheet.

CAUTION: (1) Be careful not to damage the TAB.

(2) Leave the insulation sheet on the bezel to allow the reuse of the sheet.

Product label

F9402

3

>PC GF13<-

Label (cautions for disposal of FL tubes)

BL S/N label

CAUTION label

1

2

2

 

 

Figure 4-45 Replacing 14 Inch TMD fluorescent lamp (1)