Toshiba A10 manual Procedure 2 Error Code Check, Error code Meaning

Models: A10 A1

1 417
Download 417 pages 5.8 Kb
Page 59
Image 59

2 Troubleshooting Procedures

2.3 Power Supply Troubleshooting

Procedure 2 Error Code Check

If the power supply microprocessor detects a malfunction, the DC IN icon blinks orange. The blink pattern indicates an error as shown below.

Start

Off for 2 seconds

Error code (8 bit)

 

“1”

ON for one second

“0”

ON for half second

Interval between data bits

Off for half second

The error code begins with the least significant digit.

Example:

Error code 13h (Error codes are given in hexadecimal format.)

On

1

Off Start D0

 

 

 

Read

 

 

 

1

0

0

1

0

0

0

D1

D2

D3

D4

D5

D6

D7

Order

Check 1 Convert the DC IN icon blink pattern into the hexadecimal error code and compare it to the tables below. Then go to Check 2.

DC power supply (AC adapter)

Error code

Meaning

 

 

10h

AC Adapter output voltage is over 16.5V.

 

 

11h

Common Dock output voltage is over 16.5V.

 

 

12h

Current from the DC power supply is over 6.60A.

 

 

13h

Current from the DC power supply is over 0.5A when there is no load.

 

 

14h

Abnormal current has been sensed.

 

 

2-8