April, 2007 SERVICE PROGRAM TABLES

5-39

030
CMY:LowMin. No information is available at this time.
[0~50/0.1V]
031
CMY:MidMin. No information is available at this time.
[0~50/0.1V]
032
Base MaxDiff No information is available at this time.
[0~50/0.1V]
033
Patch Mini Gap No information is available at this time.
[0~50/0.1V]
034
Light Target Adj Sets the target value for the intensity of the MUSIC sensor
lights.
[0~50/0.1V]
035
MY Light Max Sets the maximum value for the intensity of the MUSIC
sensor lights.
[0~255/0.1V]
036
Add Upper Limit
037
Add Lower Limit
038
LaserX:FrontXf
039
LaserX:CenterXc
040
LaserX: RearXr
041
LaserX: TempCoeff
No information is available at this time.
2154
2-Point Target 2-Point Interval Target Setting
These 2-point target settings done at the factory affect the characteristics of the
lenses. These target values must be entered when when the laser unit is replaced.
The correct settings are printed below the first barcode on one A5 sheet of paper
provided with the replacement laser unit.
001
K [60700~63230/61984/1]
002
M
003
C
004
Y
2155 2-Point Int Set 2-Point Interval Target Setting DFU
These SPs adjust the difference in the position of color registration for MUSIC in
the main scan direction, using K (black) as the reference point.
Do SP2109 002 and print Pattern 1 on A3/DLT size paper. Examine the pattern
with a scaled lupe. For every 43.2µm adjust the setting in the left or right direction.
A 1 step correction corrects 50µm.
001
M Main Scan
002
C Main Scan
003
Y Main Scan
[-5~+5/1 (43.2µm)