April, 2007 SERVICE PROGRAM TABLES

5-41

027
Y Sub Skew 3 Amount of shift correction for yellow in the sub scan
direction at sensor 3.
030
MUSIC Result Displays the result of MUSIC adjustment
2182
Skew Corr Total Skew Correction Total
These SPs display the total skew correction for magenta, cyan, and yellow.
001
M [-50~+50/1 pulse]
002
C [-33~+33/1 pulse]
003
Y [-50~+50/1 pulse]
2183
2-Point Measure 2-Point Interval Measurement Monitor
These SPs allow you to set the focal points for the execution of 2-point
measurement of each color.
001
Focus Value:K [-100~+100/0.01%]
002
Focus Value:M
003
Focus Value:C
004
Focus Value:Y
2201
Set DC Charge Fixed DC Charge Setting
These SPs set the dc bias for the standard speed and low speed mode, but take
effect only when SP3501 001 is set to "1" (Fixed). The dc bias (an absolute value)
is set to +200, making the default values for each color –700. The dc bias is
normally adjusted by the process control self-check, but when automatic process
control is switched OFF (by setting SP3501 001 to "1"), these values are used for
the charge potential.
001
Std Speed:K [-999 to –200/1V]
002
Std Speed:M
003
Std Speed: C
004
Std Speed: Y
006
Low Speed:K
007
Low Speed: M
008
Low Speed: C
009
Low Speed: Y
2202 Set AC Charge Fixed DC Charge Setting
These SPs set the AC bias for the standard speed mode and low speed mode,
but take effect only when SP3501 001 is set to "1" (Fixed). The default ac bias for
each color is 2.2 kV (220) The ac bias is normally adjusted by process control
self-check, but when automatic process control is switched OFF (by setting
SP3501 001 to "1"), these values are used for the charge potential.
001
Std Speed: K [0~300/1 kV]
002
Std Speed: M
003
Std Speed: C
004
Std Speed: Y
006
Low Speed: K
007
Low Speed: M
008
Low Speed: C
009
Low Speed: Y